2500 GALLON TANK INSTALLATION - Continued
TANKER PIPING INSTALLATION - Continued

Hemtt Tanker Armor Module Kit 5Sk319 Kit, Armor, Tan 5Sk320 Kit, Armor, Green Page Navigation
  309    310    311    312    313  314  315    316    317    318    319  
img
TB 9-2320-279-13&P
0040
TANKER PIPING INSTALLATION
3.
Do not tear or otherwise damage coupling gaskets during installation. If damaged coupling gasket
is used, piping connection will leak.
4.
Do not pinch or pull coupling gaskets off center when coupling halves are installed. If gasket is
damaged or moved out of position, piping connection will leak.
5.
Use petroleum jelly to lubricate gasket.
Align pipes (11 and 12) and install coupling gasket (13) over connections of pipes.
Install two coupling halves (14) on coupling gasket (13) with two screws (15) and nuts (16).