TM 9-2320-363-34-2
WATER PUMP REPAIR (CONT)
NOTE
Make sure all old Form-A-Gasket material has been removed from water seal
bore.
13. APPLY THIN FILM OF FORM-A-GASKET TO WATER SEAL BORE (15) IN WATER PUMP HOUSING (8).
C A U T I O N
Make sure water pump shaft is supported by holding fixture extension to
prevent damage to equipment.
14. POSITION WATER SEAL (14) OVER SQUARE END OF WATER PUMP SHAFT (3) WITH CLOSED
END OF WATER SEAL DOWN.
15. USING
UNTIL
BORE.
12-200
WATER SEAL INSTALLER (16), PRESS WATER SEAL (14) IN WATER PUMP SEAL BORE
WATER SEAL INSTALLER (16) BOTTOMS AGAINST WATER PUMP HOUSING (8) SEAL
REMOVE WATER SEAL INSTALLER (16).