TM 9-2320-363-34-2
C A U T I O N
Be careful when applying sealer. Too much can cause damage to sealing
surface.
16. APPLY ONE DROP OF SEALER TO WATER SEAL AND WATER PUMP SHAFT CONTACT AREA
(17). WIPE OFF EXCESS SEALER WITH CLEAN, LINT-FREE SHOP RAG OR PAPER TOWEL.
C A U T I O N
Wait 2 hours after applying primer. Water pump shaft must remain vertical
and must not be rotated or moved to prevent damage to equipment.
NOTE
Shaft should not be turned, moved from vertical, or seal-pressure tested for at
least 2 hours to allow time for curing. Do not exceed 25 psi (172 kPa) when
pressure testing.
Due to time required for curing, maintenance units should keep spare pumps
for immediate use when needed. Pump removed from an engine could be
rebuilt and placed in storage for later use.
17. APPLY SMALL AMOUNT OF PRIMER TO WATER SEAL AND WATER PUMP SHAFT CONTACT
AREA (17) WHERE SEALER WAS APPLIED.
12-201