TM 9-2320-302-20
0119 00-10
ELECTRICAL CONNECTORS MAINTENANCE - CONTINUED
0119 00
COMMERCIAL CONNECTOR REPAIR - CONTINUED
(8)
Release crimping tool with lock lever located between handles, in case of jamming.
NOTE
For ECM 30-pin connectors, put locking tang opposite lettered side.
(9)
Align locking tang of terminal with lettered side of connector.
(10)
Pull cable back through connector until a click is heard (Figure 5). Position seal into connector.
Figure 7. Pulling Terminal to Seat.
c.
Removal and Repair. A tang on terminal locks into a tab molded into plastic connector to retain cable assembly.
Remove Metri-Pack 150 terminals using the following instructions:
(1)
Insert removal tool into cavity of connector, placing tip of tool between locking tang of terminal and wall
of cavity (Figure 6).
PULL CABLE UNTIL
TERMINAL CLICKS
INTO PLACE