TB 9-2320-360-13&P-1
0034 00
REMOVAL
N OT E
Disconnect valves are closed by turning handle clockwise.
Mark locations and remove cushion clamps and screws, as required.
Mark location and cut plastic ties as required.
Cap and plug all lines and fittings.
1.
Remove two caps (1 and 2) and close two shutoff valves (3 and 4).
2.
Remove shutoff valve (3), #8 O-ring (5), and hose (6) from shutoff valve (4). Discard O-ring.
HETF00394
3.
Remove two caps (7 and 8) and close two shutoff valves (9 and 10) on firewall (11).
4.
Remove shutoff valve (9) and hose (12) from shutoff valve (10) and #12 O-ring (13). Discard O-ring.
HETF00397
0034 00-2