TM 9-2320-363-34-1
NOTE
Do not use rags or cloth towels for cleaning.
CLEAN RETARDER SOLENOID HOUSING BORE (8) IN ENGINE RETARDER ASSEMBLY HOUSING
(4) WITH CLEAN PAPER TOWELING.
1.
COAT NEW UPPER SEAL RING (5) AND NEW CENTER SEAL RING (6) WITH CLEAN ENGINE
LUBRICATING OIL AND INSTALL ON NEW SOLENOID (3).
2.
INSTALL NEW LOWER SEAL RING (7) IN BOTTOM OF RETARDER SOLENOID HOUSING BORE
(8).
C A U T I O N
Make sure seal rings are properly seated on solenoid. Take care not to twist
seal rings when installing solenoid to prevent damage to equipment.
3.
THREAD SOLENOID (3) INTO ENGINE RETARDER ASSEMBLY HOUSING (4) AND TIGHTEN TO
4-6 LB-FT (6-8 N.m).
4.
CONNECT WIRING HARNESS SOLENOID CONNECTOR (1) TO SOLENOID TERMINAL (2).
NOTE
Follow-on Maintenance:
Install rocker cover (page 3-71).
4-55/(4-56 Blank)