TM 9-2320-363-20-1
Section 4
TROUBLESHOOTING CHARTS
D. CHART 25 - FAN CONTROL MALFUNCTION (Cont'd)
Table 1: Fan Control Inputs and Outputs
Fan Mode
Fan State
Fan Control
Fan Control
A/C Input
Override
Jake Brake
Primary
Output 1
Output 2
Input
Status
Control
1 Fan
On
Open
-------
Grounded
Open
Not in High
Engine Temp
Mode
Sensors
Off
Grounded
-------
Grounded
Open
Not in High
Engine Temp
Mode
Sensors
On
Open
-------
Open
Don't
Not in High
OEM A/C
Care
Mode
Switch
On
Open
-------
Don't
Grounded
Not in High
OEM override
Care
Mode
Switch
On
Open
-------
Dont
Don't
High Mode
Jake Brake in
Care
Care
High Mode
2 Fans
1-On
Open
Open
Grounded
Open
Not in High
Engine Temp
2-On
Mode
Sensors
1-On
Open
Grounded
Grounded
Open
Not in High
Engine Temp
2-Off
Mode
Sensors
1-Off
Grounded
Open
Grounded
Open
Not in High
Engine Temp
2-On
Mode
Sensors
1-Off
Grounded
Grounded
Grounded
Open
Not in High
Engine Temp
2-Off
Mode
Sensors
1-On
Open
Grounded
Open
Don't
Not in High
OEM A/C
2-Off
Care
Mode
Switch
1-On
Open
Grounded
Don't
Grounded
Not in High
Override
2-Off
Care
Mode
Switch
1-On
Open
Grounded
Don't
Grounded
High Mode
Jake Brake in
2-Off
Care
High Mode
2 Speeds
Off
Grounded
Grounded
Grounded
Open
Not in High
Engine Temp
Mode
Sensors
Low
Open
Grounded
Grounded
Open
Not in High
Engine Temp
Mode
Sensors
High
Grounded
Open
Grounded
Open
Not in High
Engine Temp
Mode
Sensors
Low
Open
Grounded
Open
Don't
Not in High
OEM /C
Care
Mode
Switch
Low
Open
Grounded
Don't
Grounded
Not in High
Override
Care
Mode
Switch
Low
Open
Grounded
Don't
Grounded
High Mode
Jake Brake in
Care
High Mode
Change 3 3-345.175