TM 9-2320-302-34
0113 00-9
HVAC UNIT REPLACEMENT - CONTINUED
0113 00
INSTALLATION - CONTINUED
11.
Install new preformed packings (33) and lubricate them with refrigerant oil.
12.
Apply loctite to male fitting threads (34) and connect two refrigerant lines (26) to expansion valve (25). Remove tags.
13.
Torque refrigerant line connections (WP 0123 00)
14.
Apply insulation tape to refrigerant lines (26) and expansion valve (25).
15.
Connect connectors for blower motor (16), resistor block (17), and thermostatic switch (18).
16.
Connect blue air line to air cylinder behind compartment (13).
17.
Connect two flex hoses to ducts behind compartment (13).
NOTE
Any time air conditioning system is evacuated, replace receiver-drier.
18.
Replace receiver-drier (WP 0118 00).
33
34
26
25
18
16
17