W T E C I I I E L E C T R O N I C C O N T R O L S T R O U B L E S H O O T I N G M A N U A L
0011 00-67
CODE 24 XX SUMP FLUID TEMPERATURE (Figure 57)
Table 56. External Hydraulic Circuit Characteristics
Basic, PTO, 93°C (200°F) Sump Temperature
MD/B 300/B 400
CONVERTER OPERATION
MAXIMUM COOLER FLOW
AT MINIMUM PRESSURE DROP
LOCKUP OPERATION
MAXIMUM COOLER FLOW
AT MINIMUM PRESSURE DROP
Input
rpm
Flow
Pressure Drop
Input
rpm
Flow
Pressure Drop
L/s
gpm
kPa
psi
L/s
gpm
kPa
psi
600
0.10
1.6
0
0
600
0.10
1.6
0
0
800
0.23
3.7
0
0
800
0.23
3.7
0
0
1200
0.47
7.4
0
0
1200
0.50
7.9
0
0
1400
0.61
9.7
0
0
1400
0.63
10.0
0
0
1600
0.74
11.7
0
0
1600
0.77
12.2
0
0
2000
0.94
14.9
0
0
2000
0.95
15.1
0
0
2400
1.19
18.9
0
0
2400
1.12
17.8
0
0
3200
1.28
20.3
0
0
2800
1.22
19.3
0
0
3200
1.28
20.3
0
0
CONVERTER OPERATION
MAXIMUM ALLOWABLE
PRESSURE DROP
LOCKUP OPERATION
MAXIMUM ALLOWABLE
PRESSURE DROP
Input
rpm
Flow
Pressure Drop
Input
rpm
Flow
Pressure Drop
L/s
gpm
kPa
psi
L/s
gpm
kPa
psi
600
0.10
1.6
10
1.5
600
0.10
1.6
5
0.7
800
0.22
3.5
40
5.8
800
0.23
3.7
46
6.7
1200
0.45
7.1
159
23.1
1200
0.48
7.6
148
21.5
1400
0.57
9.0
252
36.5
1400
0.62
9.8
247
35.8
1600
0.67
10.6
338
49.0
1600
0.73
11.6
346
50.2
2000
0.80
12.7
481
69.8
2000
0.90
14.3
561
81.4
2400
0.85
13.5
549
79.6
2400
1.07
17.0
737
106.9
3200
0.85
13.5
549
79.6
2800
1.10
17.4
770
111.7
3200
1.10
17.4
791
114.7