DDEC TROUBLESHOOTING
[d] Specific SID
7. Adjust TRIGGER POINT: NO, or select YES and ENTER; change trigger point with
RT/LT arrow keys. ENTER.
8. WAITING FOR TRIGGER. When ready to take SNAPSHOT, apply the trigger. ANY
NUMERIC KEY overrides all other triggers.
9. PROCESSING TRIGGER; Filling remaining frames (90 frames max). When all frames
are filled, the first three lines of the TRIGGER FRAME, T, will display.
[a] To do SNAPSHOT after setup is done, do items 1, 2, and 8 only, or go to QUICK
TRIGGER and ENTER.
[b] SNAPSHOT DATA stays stored in Pro-Link memory as long as the DDR remains
powered up.
94.1.6
Print Function
Print custom data list of snapshot. The printer is attached to the DDR.
1. Select PROLINK. ENTER.
2. Select RS-232 SERIAL PORT. ENTER.
3. Select PRINTER OUTPUT. ENTER.
4. Arrow up or down to SNAPSHOT DATA. ENTER.
5. Right to CUSTOM. ENTER twice.
6. Select six items from data list using arrow up or down. ENTER after each selection.
- FUNC.
7. Type 001; ENTER; 090; ENTER.
All information subject to change without notice.
6SE497 9709 Copyright © 1997 DETROIT DIESEL CORPORATION
94-5