32.3
TROUBLESHOOTING FLASH CODE 32
6. Measure voltage between B1 and a good ground.
[a] If either measurement was greater than 0.5 volts, the wire that had the reading is
shorted to some voltage source. Replace the wire(s). Refer to section 32.3.3.
[b] If no measurement was greater than 0.5 volts, contact Detroit Diesel Technical
Service.
32.3.3
Verify Repairs
Perform the following steps to verify repairs.
1. Connect all connectors.
2. Start and run the engine.
3. Plug the diagnostic data reader (DDR) into the diagnostic data link (DDL). Read codes.
[a] If active code 32 is logged, review this section to find the error. Refer to section 32.1.
[b] If code 32 is not logged, troubleshooting is complete.
All information subject to change without notice.