Figure 12-2 Typical Variable Speed Governor Circuit
Figure 12-4 Variable Speed Governor Circuit
TM-9-2320-302-20 Truck Tractor Yard-Type: 43 500 LB GVW DED 4x2 Army Model M878A1 (Ottawa Model 60) (NSN 2320-01-121-2102) Manual
Page Navigation
220
221
222
223
224
225
226
227
228
229
230
12.3
TROUBLESHOOTING FLASH CODE 12
[b] If measured voltage is greater than 0.2 volts, signal wire is shorted to 12/24 volt
source. Repair or replace #510/#525 circuit. Refer to section 12.3.8.
Figure 12-3
Variable Speed Governor Circuit
12.3.7
Check for Short
To check for short, perform the following:
1. Turn ignition OFF.
2. Unplug vehicle 30-pin connector and the VSG connector.
3. Turn ignition ON.
4. Enable VSG. Refer to OEM guidelines.
5. Measure
resistance
between A3 (#916) and D1 (#510). See Figure 12-4.
[a] If
resistance
is greater than 5
, check ECM connector. Refer to section 12.3.8.
All information subject to change without notice.
12-8
6SE497 9709
Copyright © 1997 DETROIT DIESEL CORPORATION