TM 9-2320-302-20
0013 00-17
ANTI-LOCK BRAKE SYSTEM TROUBLESHOOTING AND TESTING - CONTINUED
0013 00
PRO-LINK SCREENS - CONTINUED
e.
Press ENTER to display stored faults as shown in Figure 21. A description of the stored fault appears. In this
example, only one fault is stored in memory, as indicated on line one. The blink code and number of times the fault
occurred also appear on line one. Lines two and three provide a written description of the fault. Press FUNC to
exit. The screen shown in Figure 22 appears if you try to clear a stored code with an existing fault present.
Figure 21. Pro-link Screen Six.
Figure 22. Pro-link Screen Seven.
f.
Remove the power from the ECU, make necessary repairs, and recycle the ECU.
4.
Clearing Stored Faults. The screens you will see when clearing stored faults are illustrated in Figures 23 and 24.
a.
Figure 23 shows there are no existing faults. Select stored faults to view and clear memory. Press FUNC to display
the menu shown in Figure 24.
Figure 23. Pro-link Screen Eight.
Figure 24. Pro-link Screen Nine.