TM 9-2320-302-10
0012 00-25
Table 1. Preventive Maintenance Checks and
Services (PMCS) for M915A3 - Continued.
Item
No.
Interval
Location
Procedure
Not Fully Mission
Capable If:
Item To
Check/
Service
46
Weekly
Ether
Quick-
start Sys-
tem
WARNING
Ether is highly flammable and explosive. DO
NOT perform ether quick-start system checks or
inspections while smoking or near fire, flame or
sparks. Failure to follow this warning may cause a
fire and explosion, causing serious injury or death
to personnel.
Check for loose connections and
damage to lines, fittings, and can-
ister. Be alert for the odor of leak-
ing ether.
Damage or leakage is
evident.
47
Weekly
Wind-
shield
Washer
Reservoir
Check level of fluid in reservoir
located in engine compartment
below driver windshield on left
firewall. Add windshield cleaning
compound (Item 3, WP 0020 00)
as required.
48
Weekly
Front
Wheel and
Tire
WARNING
Operating truck with an underinflated or defective
tire may lead to tire failure and loss of steering
control. Injury to personnel or damage to equip-
ment may result.
a. Check pressure in tires and
adjust as required:
Empty - 85 psi (586 kPa)
Loaded - 105 psi (724 kPa)
b. Ensure all wheel stud lug nuts
are tight, using wheel stud lug
nut wrench and handle.
b. Two or more wheel
studs are missing or
lug nuts are loose.
c. Check wheel for cracks, breaks,
or bends.
c. Wheel is cracked,