TM 9-2320-273-20
COOLING SYSTEM.
4-49. FAN CLUTCH ACTUATOR TUBES MAINTENANCE (M919) (Continued).
LOCATION/lTEM
ACTION
REMARKS
B. INSPECTION.
8. Tubes and fittings.
Inspect all components for
Replace if necessary.
cracks and defects.
C. INSTALLATION.
9. Four elbows (11).
Install one elbow (11) at
Coat threads with liquid
fan clutch valve (10) and
tefIon.
three elbows (11) at the
fan clutch actuator (12).
10. Connector (9).
Install in fan clutch valve
Coat threads with liquid
(10).
teflon.
11. Tube (8).
Connect at fan clutch
Coat threads with liquid
valve (10) and at fan clutch
teflon.
actuator (12).
12. Tube (5).
Connect tube (5) to con-
Coat threads with liquid
nector (7) located on fan
teflon.
clutch (6) and at fan
clutch actuator (12).
13. Tee (3).
Install tee into governor
Coat threads with liquid
(4).
teflon.
4-194