TM 9-2320-273-20
WINCH.
12-15. HYDRAULIC PUMP MAINTENANCE (Continued).
LOCATION/lTEM
ACTION
REMARKS
B. INSTALLATION (Continued).
NOTE
Be sure you connect each hose to the
proper port.
7. Two fittings (9) with two
a. Coat threads with liquid
motor lines (2) attached.
tefIon.
b. Unplug, screw in, and
tighten.
8. Pump (5).
Using funnel, pour oil from
container into top ports.
9. Two reservoir lines (7).
Attach with four clamps (8).
10. Fill cap (1).
Screw on and tighten.
C. OPERATIONAL CHECK.
11. Engine.
Start up (see TM 9-2320-273-
10). Engage PTO.
12. Winch.
Check operation.
13. Pump (5).
Check for leaks.
Retighten connections as
necessary.
14. Engine.
Disengage PTO and shut down
(see TM 9-2320-273-10).
NOTE
Use sight glasses to check oil level in
reservoir. Add oiI if necessary (refer
to LO 9-2320-273-12).
12-44