TM 5-2330-325-14&P
2-15.
COUPLING GOOSENECK TO PRIME MOVER AND RAISING TRAILER (Continued).
(5)
Connect the 12-volt (15) and 24-volt (16) electrical cables from the prime mover to the
gooseneck electrical connectors. Also check to be sure the 12/24-volt electrical cable (6) is
connected between the trailer and the gooseneck.
(6)
Connect the blue service and red emergency air lines from the prime mover to the
respective gooseneck blue (14) and red (13) gladhands. Also check to be sure the air lines
(7 and 9) are connected between the trailer and the gooseneck.
NOTE
Rotate female hydraulic connector 90 after connecting to gooseneck to
avoid possible damage during transport.
(7)
Remove hydraulic return line connector dust cover and wipe connector clean. Connect the
hydraulic return line from the prime mover to the gooseneck hydraulic return connector
(12).
(8)
Remove hydraulic inlet line connector dust cover and wipe connector clean. Connect the
hydraulic inlet line from the prime mover to the gooseneck hydraulic inlet connector (11).
NOTE
Be sure that the level for hydraulic fluid in reservoir of the prime mover is
above the minimum level to avoid getting air in the hydraulic lines.
2-32