TM 9-2320-363-34-1
Oil Level Gage Depth
Oil Quantity
In Inches (mm)
In Fluid Oz (ml)
7/8 in. (22.2 mm)
6 fl oz (177 ml)
1 in. (25.4 mm)
8 fl oz (237 ml)
1
118 in. (28.6 mm)
10 fl oz (296 ml)
1 7/16 in. (36.5 mm)
12 fl oz (355 ml)
1
1 1/16 in. (43 mm)
14 fl oz (414 ml)
3.
ADD OR REMOVE OIL FROM COMPRESSOR (2) SO THAT OIL CHARGE IN COMPRESSOR IS
10 fl oz (296 ml).
4.
ADD ADDITIONAL OIL TO COMPRESSOR (2) BASED ON NUMBER OF MAJOR AIR
CONDITIONING COMPONENTS REPLACED. TOTAL CHARGE SHOULD BE 14 fl oz (414 ml)
5.
ENSURE THAT PREFORMED PACKING AND THREADS OF OIL FILL PLUG (1) ARE CLEAN.
BEING CAREFUL NOT TO TWIST PREFORMED PACKING, INSTALL OVER THREADS OF OIL
FILL PLUG. INSTALL OIL FILL PLUG AND TIGHTEN SNUGLY.
Charge and leak test
NOTE
Follow-on Maintenance:
air conditioning system (page 11.1-2 and TM 9-2320-363-20).
Change 1
11.1-25/(11.1-26 Blank)