PLACE OIL PUMP BODY (1), COVER SIDE DOWN, ON PRESS SUPPORT.
APPLY THIN FILM OF LUBRIPLATE 105 TO BUSHING BORES (2).
POSITION BUSHINGS (3) LOOSELY OVER PUMP BODY BUSHING BORES (2).
ROTATE BUSHINGS (3) SO SPLIT LINES (4 AND 5) ARE PARALLEL WITH MACHINED SURFACE
(6) OF PUMP BODY.
WHEN PROPERLY ALlNED, SPLIT LINE (4) SHOULD MEASURE 0.461 IN. (11.705 mm) TO
SURFACE (6). SPLIT LINE (5) SHOULD MEASURE 1.726 IN. (43.82 mm) TO SURFACE (6).
NOTE
Bushings must be installed flush to specified depth below finished surface of
pump body.
PRESS BUSHINGS (3) IN PUMP BODY BUSHING BORES (2) NOT MORE THAN 0.031 IN. (0.8 mm)
BELOW FINISHED SURFACE OF OIL PUMP BODY (1).