TM 9-2320-363-20-1
Table 3-1. Troubleshooting (Cont)
Malfunction
Test or inspection
Corrective action
ELECTRICAL SYSTEM (CONT)
Ether Quick-Start Circuit
1. ETHER QUICK-START NOT OPERATING, CONTAINER HAS ETHER IN IT.
Step 1.
Check ether 15A fuse.
If defective, replace 15A fuse (page 4-204).
Step 2.
Remove ether 15A fuse. Check for +12 VDC at fuse connector from ignition
run power bus.
If +12 VDC is present, go to step 3. If no voltage is present,
repair circuit 18 (page 3-2).
Step 3.
Disconnect lead 166 from ether switch. Check for +12 VDC at lead 166.
If +12 VDC is present, go to step 4. If no voltage is present,
repair lead 166 (page 3-2).
Step 4.
Disconnect lead 166 and lead 166A from ether switch. Check for continuity
between contacts of switch with switch activated.
If continuity is present, go to step 5. If no continuity is
indicated, replace ether switch (page 4-188).
Step 5.
Disconnect lead 166A at cab/chassis connection. Check for +12 VDC at
lead 166A.
If +12 VDC is present, go to step 6. If no voltage is present,
repair lead 166A (page 3-2).
Step 6.
Disconnect lead 166A from ether solenoid. Check for +12 VDC at lead 166A.
If +12 VDC Is present, go to step 7. If no voltage is present,
repair lead 166A (page 3-2).
3-68