TM 9-2320-302-10
0004 00-12
DESCRIPTION AND USE OF OPERATOR'S CONTROLS
AND INDICATORS - CONTINUED
0004 00
INSTRUMENT PANEL - CONTINUED
4.
Lower Right Dash Panel.
Key
Control or Indicator
Function
28
Wiper/Washer
Control
Turns windshield wipers on/off. Clockwise is ON.
Counterclockwise is OFF. To wash windshield, press
knob in to spray water and to turn wipers on.
29
Mirror Heat Switch
ON/OFF toggle switch controls mirror heat for
defrosting.
30
Auxiliary Heater
Indicator Light
(if equipped)
Lights up when arctic heater burner is lit.
31
Auxiliary Heater
Control Switch
(if equipped)
Operates arctic heater. Positions are ON and OFF.
When set to ON, a green light integrated into switch
is illuminated.
32
HI-LO Switch
(if equipped)
Controls rate of heating for arctic heater. If set at HI,
heater burner will go on when coolant temperature at
inlet to heater is 167°F (75°C). LO is suitable for
standby operation.
37
28
30
31
32
33
34
35
29
36