TM 5-2330-325-13&P
OPERATOR MAINTENANCE
BRAKES FAIL TO ENGAGE
INITIAL SETUP:
References
TROUBLESHOOTING PROCEDURE
SYMPTOM
BRAKES FAIL TO ENGAGE
MALFUNCTION
CONTROL AIR LINE NOT CONNECTED
CORRECTIVE ACTION
1.
If line is not properly connected, remove and reconnect.
2.
If no air is flowing from towing vehicle, notify Field Maintenance and use another
towing vehicle.
MALFUNCTION
DIRTY OR DAMAGED PACKING
CORRECTIVE ACTION
1.
2.
If packing is leaking, notify Field Maintenance.
MALFUNCTION
DAMAGED CONTROL AIR LINE
CORRECTIVE ACTION
Notify Field Maintenance.
MALFUNCTION
DAMAGED OR MISSING BRAKE SYSTEM COMPONENTS
CORRECTIVE ACTION
Notify Field Maintenance.
0013-1
02/13/2013root(tswp)wpno(T1007)