M1070 HET ARMOR KIT
II113400
Rev. D
3. Install right aft side panel assembly as follows (see Figure 3-24):
NOTE
Repositioning of 90-degree joiner brackets may be required to provide adequate
clearance while mounting the right aft side panel assembly.
a. Install three flat washers (1) onto each stud along left side of cab on roof panel.
b. Using appropriate lifting device, hardware, and personnel, lift right aft side panel assembly into position
onto cab.
c. Verify holes in right aft side panel assembly for grab handle and seat belt attachments are aligned with
holes in cab.
d. Slide both bottom 90-degree joiner brackets firmly into position against cab frame rail and torque bracket
locknuts to 23 lb-ft.
e. Install six flat washers (1) and locknuts (2) onto studs of two 90-degree joiner brackets. Do not tighten at
this time.
f.
Install eight flat washers (1) and locknuts (1) onto top row of studs on roof armor. Do not tighten at this
time.
INSTALLATION 3-48
JUNE 2005