TB 9-2320-360-13&P-1
A/C PRESSURE SWITCH REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Maintenance Level
Materials/Parts - Continued
Switch, Pressure (Item 39, Figure 1, WP 0062 00)
Unit Maintenance
Tags, Identification (Item 14, WP 0061 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanic (Item 12, WP 0060 00)
Wheels chocked (TM 9-2320-360-10)
Materials/Parts
Hood opened (TM 9-2320-360-10)
Sealing Compound (Item 2, WP 0061 00)
Batteries disconnected (TM 9-2320-360-20-2)
REMOVAL
WAR N I N G
Use care to prevent refrigerant from touching your skin or eyes. Liquid refrigerant, when exposed to air,
quickly evaporates and will freeze skin or eye tissues. Serious injury or blindness may result if you come in
contact with liquid refrigerant.
Refrigerant R-134a A/C systems should not be pressure tested or leak tested with compressed air. Combustible
mixtures of air and R-134a may form, resulting in a fire or explosion, which could cause personnel injury or
death.
N OT E
Tag and mark all wires prior to removal.
1.
Disconnect pressure switch connector (1) from wiring
harness.
2.
Remove pressure switch (2) from receiver/dryer (3).
HETF00315