TB 9-2320-302-13&P-3
A/C HOSE REPLACEMENT - CONTINUED
0020 00
REMOVAL - CONTINUED
WARNING
Contact with refrigerant can cause frostbite. Keep hands and face away to prevent personal injury.
Protective face shield must always be worn when refrigerant lines are opened, even if the gauges indi-
cate the system is empty.
Always use caution if a fitting is removed. Slowly loosen the fitting. If the system is still under any
pressure, release it slowly in a well-ventilated area.
DO NOT smoke when servicing A/C or wherever refrigerant gas may be present.
Failure to follow these warnings may result in injury or death to personnel.
CAUTION
Cap all A/C hose ends and component connections during installation to protect against contamination. Fail-
ure to comply may cause damage to equipment.
NOTE
Tag wires and hoses to aid in installation.
Note routing of wires and hoses prior to removal to aid installation.
1.
Remove A/C hose (2) connection from condenser (1). Discard O-rings.
2.
Remove A/C hose (3) connection from condenser (1). Discard O-rings.
3.
Remove tiedown straps (4) and spiral wrap (5) as necessary from A/C hoses (2 and 3). Discard tiedown straps.
2
1
449-056
4,5
3
0020 00-2