TB 9-2320-302-13&P-1
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
Location
Item To
Check/
Item
Not Fully Mission
Service
No.
Interval
Procedure
Capable If:
3
Before
Floor /Fire-
a. Inspect left side floor and firewall Any panel or armor plate is damaged,
wall Armor
armor panels for damage or loose or bent out of shape, misaligned, loose or
(Left Side)
missing mounting hardware.
missing, or mounting bolts are loose or
missing.
b. Inspect left side floor and firewall Any corrosion where area is unsound
panels for areas of rust or corrosion.
and small pin holes are present, or a
rusted through condition is present.
c. Inspect left side floor and firewall Any cracks that are longer than 1" or
armor panels for cracks near or elon- two consecutive bolt holes that are elon-
gation of bolt holes.
gated.
d. Inspect left side floor and firewall Any complete penetration of the armor
armor panels for any holes or gouges. (hole in the armor) or multiple gouges
1/4" or deeper within 3" of each other.
e. Inspect fuse access panel and support Any damaged to access panel or mount-
for damaged, loose, or missing ing hardware is loose or missing.
mounting hardware.
FIREWALL ARMOR
ACCESS PANEL
FLOOR ARMOR
417-268
0009 00-6